Skip to content
VOXELIA 3D

Practical guide · Flat roof, slope and delivery

Review flat roof drainage in a 3D model

A 3D as-built model from supplied imagery makes slope directions, low points, roof obstructions, parapets, drain zones and ponding risks visible for planning. Voxelia turns imagery into CAD, orthophoto, viewer and BIM-oriented deliverables without replacing specialist drainage design.

  • 12 min read
  • Voxelia 3D
  • Germany, Austria & Switzerland
  • KOSTRARain basis

    DWD source for heavy rainfall data

  • Δh/LSlope logic

    height difference divided by distance

  • CAD + 3DDelivery

    low points, drains, edges and zones

Why flat roof drainage is a 3D topic

3D model of an office building with flat roof and rooftop equipment
Flat roof · real project3D model of a flat roof with rooftop equipment — the basis for the drainage review.

Flat roof drainage depends on small height differences, low points, parapets, roof penetrations, PV substructures and existing refurbishment layers. A single photo or old 2D plan rarely explains that geometry reliably.

Voxelia processes supplied imagery into measurable 3D models, orthophotos, height context, marked risk areas and CAD or viewer deliverables. Drain sizing and compliance remain with qualified specialists.

What the 3D model makes visible

A useful model turns the roof into readable terrain: high edges, low zones, flow directions, drains, upstands, transitions, parapets and adjacent components can be reviewed together.

The strongest delivery combines orthophoto and 3D height context. The orthophoto shows drains, seams and equipment; the model adds spatial logic for early slope checks and coordination.

Review matrix for roofers, PV teams and planners

ReviewModel valueInput dataLimit
Slope direction and low pointsHeight model and sections show likely flow paths.3D model, orthophoto, reference dimensionsSmall height differences require strong references.
Drains and emergency overflowsLocations and potential obstructions become visible.Orthophoto, detail photos, CAD marksSizing remains specialist design.
Flat roof PV layoutModule fields and service paths can be checked against drainage zones.3D roof model, CAD/DXF, roof obstructionsYield, structural and fire safety checks are separate.
Refurbishment planningExisting heights and problem zones structure the takeoff.Point cloud, sections, orthophotoMoisture, layers and waterproofing need expert inspection.

Workflow: from imagery to drainage planning base

  1. Define the question

    Collect drains, parapets, low points, PV zones, service paths and known ponding areas as review targets.

  2. Check imagery and references

    We review sharpness, overlap, coverage, metadata, reference dimensions and whether drainage areas are visible.

  3. Build model and orthophoto

    Suitable imagery becomes mesh, point cloud, orthophoto and height context.

  4. Mark slope and risk zones

    Low points, flow paths, upstands, obstructions and ponding risks are marked in the delivery.

  5. Export the delivery

    Viewer, screenshots, DXF/DWG, point cloud, orthophoto or BIM-oriented data are prepared for the next workflow.

Standards, heavy rain and responsibility

Drainage design depends on standards and local rain data. DIN Media lists DIN EN 12056-3 for roof drainage. In Germany, DIN 1986-100 is also used in practice for site drainage and emergency drainage context.

For design rainfall, KOSTRA-DWD 2020 is the official German Weather Service basis for regional heavy rainfall values. The 3D model supports the geometry; specialists remain responsible for sizing and compliance.

Useful deliverables for refurbishment, PV and as-built review

Roofers often need CAD-ready edges, drains, obstructions and marked problem areas. PV teams also need drainage zones, service paths and module fields in one planning context.

Voxelia can prepare orthophotos, point clouds, meshes, DXF/DWG, BIM-oriented files or a web viewer, depending on the downstream workflow.

FAQ: flat roof drainage from 3D models

Can Voxelia calculate my roof drainage?
Voxelia creates the geometric planning base from imagery. Drain sizing and compliance must be handled by qualified specialists.
Are existing photos enough?
Often they are enough for an initial review if the roof, drains, edges and obstructions are fully visible with good overlap and reference dimensions.
Does this help with ponding water?
Yes. The model can show low points, ponding zones and blocked paths, but it does not automatically identify material or waterproofing causes.
Is this relevant for flat roof PV?
Yes. PV layouts should consider drainage paths, service routes and low points. A 3D delivery helps review these together.
  • Flat Roof
  • Drainage
  • 3D Model
  • CAD
  • PV Planning

Related

Related guides

Get started

The first project is on us.

Upload your drone photos. Standard projects are ready in 24–48 hours – for PV*SOL, AutoCAD, GIS or the browser.

First project without a credit card · then from €45 per project · no subscription needed

Keep this ready

Keep the prepared €45 pilot by email

We keep package, scope, and article context. If you do not pay now, the prepared Stripe link can come back later.